Fault fltFvRsDomAttInvalidConfigOnRsDomAtt
                
                    
                         Explanation:  
This fault occurs when there are specific configuration errors on EPG to VMM Domain Association.
 
                         Recommended Action:  
            If you see this fault, take the following actions:
             
Fault Name: fltFvRsDomAttInvalidConfigOnRsDomAtt
                         Unqualified API Name: InvalidConfigOnRsDomAtt
                         
                         Code: F2531
                         
                         Applied Mo DN Format: 
                         
                                  topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/ap-[name]/epg-[name]/rsdomAtt-[tDn]
                             
                                  uni/tn-[name]/ap-[name]/epg-[name]/rsdomAtt-[tDn]
                             
                         
                         Type: config
                         
                         Cause: config-error
                         
                         Severity: minor
                         
                         Weight: 100
                         
                         Tags: 
                         
                         Message: 
Configuration is invalid due to configIssues.
                         
                         Help: 
                         
                         
                         Triggered By: 
                         
                                    configIssues not equals none