Fault fltCnwPhysIfPortOutofService
                

Rule ID:106


Explanation:
This fault occurs when a port is out-of-service because of a wiring error.

Recommended Action:
If you see this fault, take the following actions:


  1. Ensure the device connected to the port is the correct device.
  2. Ensure the device connected to the port is configured properly for the fabric it is being connected to.
  3. If the device being connected is being reprovisioned from another fabric, ensure that the config on that device has been factory reset
  4. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: cnw:PhysIf

Fault Name: fltCnwPhysIfPortOutofService

Unqualified API Name: portOutofService
Code: F0106
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/cphys-[id]
     sys/cphys-[id]

Type: config
Cause: wiring-check-failed
Severity: critical
Weight: 100
Tags:
Message: Physical Interface id on Node id is out of service. Reason: wiringIssues

Help:

Triggered By:
         wiringIssues not equals 0
        and
         wiringIssues not equals none