Fault fltLldpIfPortOutofService
                

Rule ID:454


Explanation:
This fault occurs when a port is out-of-service because of a wiring error.

Recommended Action:
If you see this fault, take the following actions:


  1. Ensure the device connected to the port is the correct device.
  2. Ensure the device connected to the port is configured properly for the fabric it is being connected to.
  3. If the device being connected is being reprovisioned from another fabric, ensure that the config on that device has been factory reset
  4. If above actions did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: lldp:If

Fault Name: fltLldpIfPortOutofService

Unqualified API Name: portOutofService
Code: F0454
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/lldp/inst/if-[id]
     sys/lldp/inst/if-[id]

Type: config
Cause: wiring-check-failed
Severity: major
Weight: 100
Tags:
Message: Port id is out of service due to wiringIssues

Help:

Triggered By:
         wiringIssues not equals none
        and