Fault fltPcAggrMbrIfPortIndividual
                

Rule ID:603


Explanation:
This fault occurs when port becomes operationally individual.

Recommended Action:
Please verify the configuration on both ends of the port-channel.


Raised on MO: pc:AggrMbrIf

Fault Name: fltPcAggrMbrIfPortIndividual

Unqualified API Name: portIndividual
Code: F0603
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/phys-[id]/aggrmbrif
     sys/phys-[id]/aggrmbrif

Type: communications
Cause: interface-pcmbr-down
Severity: minor
Weight: 100
Tags:
Message: Port is operationally individual.

Help:

Triggered By:
         operSt not equals up
        and
         pcMode not equals mac-pin
        and
         channelingSt equals individual