Fault fltArpStAdjEpOperStDown
                

Rule ID:1207


Explanation:
This fault occurs when the operational state of the arp adjacency is down

Recommended Action:
To recover from this fault, try the following actions


  1. Look at any configuration issues
  2. Verify the configuration is correct/complete
  3. Ensure the port is up on which ARP is configured

Raised on MO: arp:StAdjEp

Fault Name: fltArpStAdjEpOperStDown

Unqualified API Name: operStDown
Code: F1207
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/arp/inst/dom-[name]/if-[id]/sadj-[ip]
     sys/arp/inst/dom-[name]/if-[id]/sadj-[ip]

Type: operational
Cause: protocol-arp-adjacency-down
Severity: warning
Weight: 100
Tags:
Message: Static ARP adjacency is operSt, reason operStQual

Help:

Triggered By:
        operSt equals down