Fault fltFabricOosPathIssuesConfig-failed
                

Rule ID:1209


Explanation:
This fault occurs when an out-of-service policy is incorrectly configured.

Recommended Action:
If you see this fault, take the following actions:


  1. Look at the configuration for issues
  2. For invalid-path, confirm that the specified interface is correct
  3. For further details, refer to the documentation for fabric:PathIssues
  4. Verify the fabric selector configuration is correct and complete
  5. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: fabric:OosPathIssues

Fault Name: fltFabricOosPathIssuesConfig-failed

Unqualified API Name: config-failed
Code: F1209
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/fabric/outofsvc/rsoosPath-[tDn]/pathissues
     uni/fabric/outofsvc/rsoosPath-[tDn]/pathissues

Type: config
Cause: configuration-failed
Severity: minor
Weight: 100
Tags:
Message: Configuration failed for node name, name tDn due to configQual

Help:

Triggered By:
        configSt equals failed-to-apply