Fault fltFabricLinkFailed
                

Rule ID:1239


Explanation:
This fault occurs when a link state is not ok

Recommended Action:
If you see this fault, take the following action:


  1. check if connectivity between the nodes for the link is ok. check if there is any mismatch of fabricDomain and infraVlan between APIC and leaf. fabricDomain and infraVlan mismatch usually happens when a new leaf/APIC added to the existing fabric. If a new leaf from another fabric with different fabricDomain and infraVlan added then clean reboot the leaf. If a new APIC added then the fabricID and infraVlan should match with existing fabric.
  2. If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.


Raised on MO: fabric:Link

Fault Name: fltFabricLinkFailed

Unqualified API Name: Failed
Code: F1239
Applied Mo DN Format:
     topology/pod-[id]/lnkcnt-[n]/lnk-[n1]-[s1]-[p1]-to-[n2]-[s2]-[p2]

Type: environmental
Cause: link-failed
Severity: critical
Weight: 100
Tags:
Message: Link between node n1 slot s1 port p1 and node n2 slot s2 port p2 is invalid. wiringIssues

Help:

Triggered By:
         linkState not equals ok