Fault fltMgmtConfigAddrDuplicateMgmtAddr
                

Rule ID:1726


Explanation:
This fault occurs when the same IP address is configured on multiple nodes.

Recommended Action:
If you see this fault, take the following actions:


  1. Identify the nodes that are using the same IP address.
  2. Fix address pools, or the static IP that is assigned to the conflicting nodes.
  3. If above actions did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: mgmt:ConfigAddr

Fault Name: fltMgmtConfigAddrDuplicateMgmtAddr

Unqualified API Name: duplicateMgmtAddr
Code: F1726
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/instp-[epgPKey]/addrcont/caddr-[addr]
     uni/epp/instp-[epgPKey]/addrcont/caddr-[addr]
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/inb-[epgPKey]/addrcont/caddr-[addr]
     uni/epp/inb-[epgPKey]/addrcont/caddr-[addr]
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/oob-[epgPKey]/addrcont/caddr-[addr]
     uni/epp/oob-[epgPKey]/addrcont/caddr-[addr]
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/addrcont/caddr-[addr]
     uni/epp/addrcont/caddr-[addr]

Type: config
Cause: configuration-failed
Severity: minor
Weight: 100
Tags:
Message: Duplicate IP address: descrDuplicate out-of-band management address: descrDuplicate in-band management address: descr

Help:

Triggered By:
        numProvs not equals 1