Fault fltEqptdiagSubjOperStFailed
                

Rule ID:2421


Explanation:
This fault occurs when a diagnostic test fails.

Recommended Action:
The failed diagnostic test isolates the error to a port, card(FRU) or the entire switch. For port-level errors, the port are put in disabled state. For card or switch level errors, collect the show techsupport command output on the switch and contact Cisco TAC to eliminate any known software issues before replacing the hardware.


Raised on MO: eqptdiag:Subj

Fault Name: fltEqptdiagSubjOperStFailed

Unqualified API Name: operStFailed
Code: F2421
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/diag/rule-[type]-trig-[trig]/subj-[oDn]
     sys/diag/rule-[type]-trig-[trig]/subj-[oDn]

Type: operational
Cause: equipment-diags-failed
Severity: minor
Weight: 100
Tags:
Message: Diagnostics test failed. reason:operStQual

Help:

Triggered By:
        operSt equals fail