Fault fltVsanmgrInstVsanCreateFailedLimitReached
                

Rule ID:2438


Explanation:
This fault occurs when a Created Vsan count exceeds allowed limit on node

Recommended Action:
If you see this fault, take the following actions


  1. Check the number of allowed VSANS and deleted unused VSAN from node
  2. Please note if you configure more than supported VSANS first #num supported vsans will be created you could loose a working VSAN after switch reload.
  3. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.

Raised on MO: vsanmgr:Inst

Fault Name: fltVsanmgrInstVsanCreateFailedLimitReached

Unqualified API Name: VsanCreateFailedLimitReached
Code: F2438
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/vsanmgr/inst
     sys/vsanmgr/inst

Type: communications
Cause: vsan-failure
Severity: minor
Weight: 100
Tags:
Message: Configured Vsan not UP , reason:Vsan configuration limit exceeded

Help:

Triggered By:
          numCreatedVsan equals 36u
        or
          numCreatedVsan greater than 35u