Fault fltFvRsDomAttInvalidConfigOnRsDomAtt
                

Rule ID:2531


Explanation:
This fault occurs when there are specific configuration errors on EPG to VMM Domain Association.

Recommended Action:
If you see this fault, take the following actions:


  1. Change deployment immediacy to immediate and check if fault is cleared
  2. If the above action did not resolve the issue, create a tech-support


Raised on MO: fv:RsDomAtt

Fault Name: fltFvRsDomAttInvalidConfigOnRsDomAtt

Unqualified API Name: InvalidConfigOnRsDomAtt
Code: F2531
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/ap-[name]/epg-[name]/rsdomAtt-[tDn]
     uni/tn-[name]/ap-[name]/epg-[name]/rsdomAtt-[tDn]

Type: config
Cause: config-error
Severity: minor
Weight: 100
Tags:
Message: Configuration is invalid due to configIssues.

Help:

Triggered By:
        configIssues not equals none