Fault fltFhsIpInspectOperStDown
Explanation:
This fault occurs when the
operational state of the ip inspect feature is changed
to due to either cfg-err or bd-max-binding-limit-exceeded or
epg-max-binding-limit-exceeded or
mac-max-binding-limit-exceeded reasons
Recommended Action:
To recover from this fault,
try the following actions
Fault Name: fltFhsIpInspectOperStDown
Unqualified API Name: operStDown
Code: F2674
Applied Mo DN Format:
topology/pod-[id]/node-[id]/sys/fhs/inst/dom-[encap]/bd-[encap]/ipinspect-[af]
sys/fhs/inst/dom-[encap]/bd-[encap]/ipinspect-[af]
Type: operational
Cause: oper-state-failed
Severity: major
Weight: 100
Tags:
Message:
Operational State of IpInspect feature operationally down, reason:operStQual
Help:
Triggered By:
operStQual equals cfg-error
or
operStQual equals bd-max-binding-limit-exceeded
or
operStQual equals epg-max-binding-limit-exceeded
or
operStQual equals mac-max-binding-limit-exceeded