Constants |
cleared |
0 |
cleared |
The Cleared severity level indicates the clearing of one or more previously reported alarms. This
alarm clears all alarms for this managed object that have the same Alarm type, Probable cause and
Specific problems (if given). Multiple associated notifications may be cleared by using the Correlated
notifications parameter (defined below).
|
info |
1 |
info |
NO COMMENTS
|
warning |
2 |
warning |
The Warning severity level indicates the detection of a potential or impending service affecting
fault, before any significant effects have been felt. Action should be taken to further diagnose (if
necessary) and correct the problem in order to prevent it from becoming a more serious service affecting
fault.
|
minor |
3 |
minor |
The Minor severity level indicates the existence of a non-service affecting fault condition and that
corrective action should be taken in order to prevent a more serious (for example, service affecting) fault.
Such a severity can be reported, for example, when the detected alarm condition is not currently
degrading the capacity of the managed object.
|
major |
4 |
major |
The Major severity level indicates that a service affecting condition has developed and an urgent
corrective action is required. Such a severity can be reported, for example, when there is a severe
degradation in the capability of the managed object and its full capability must be restored.
|
critical |
5 |
critical |
The Critical severity level indicates that a service affecting condition has occurred and an
immediate corrective action is required. Such a severity can be reported, for example, when a managed
object becomes totally out of service and its capability must be restored.
|
inherit |
7 |
inherit |
NO COMMENTS
|
DEFAULT |
inherit(7) |
inherit |
NO COMMENTS
|