Fault fltTunnelIfTunnelDown
                

Rule ID:2821


Explanation:
This fault occurs when the tunnel is down because the tunnel was not configured correctly.

Recommended Action:
If you see this fault, take the following actions:


  1. To correct this fault, please attempt to create the tunnel again
  2. If the above actions did not resolve the issue, collect a tech-support file and contact Cisco TAC.


Raised on MO: tunnel:If

Fault Name: fltTunnelIfTunnelDown

Unqualified API Name: tunnelDown
Code: F2821
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/tunnel-[id]
     sys/tunnel-[id]

Type: communications
Cause: interface-tunnel-down
Severity: major
Weight: 100
Tags:
Message: Tunnel is down, reason:operStQual

Help:

Triggered By:
         operSt equals down
        and
         operStQual not equals desip-unres
        and
         operStQual not equals dest-unreach
        and
         operStQual not equals hwprog-fail