Fault fltPcLbPEltmCfgCtrl
                

Rule ID:2805


Explanation: This fault is caused by a hardware programming failure
Recommended Action: The system will periodically retry to program the hardware. If the failure is due to lack of hardware resources, free up resources by removing or simplifying existing configuration. One of the reasons for lack of hardware resources is exhaustion of VLANs in ToR. These hardware resources can be examined by looking at capacity dashboard under OPERATIONS tab. Please check entry against the number of VLANs in output of command show vlan summary issued at node where fault is generated to check whether it exceeds above advertised node capacity.

Raised on MO: pc:LbP

Fault Name: fltPcLbPEltmCfgCtrl

Unqualified API Name: eltmCfgCtrl
Code: F2805
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/aggr-[id]/lb
     sys/aggr-[id]/lb

Type: config
Cause: config-failure
Severity: warning
Weight: 100
Tags:
Message: Symmetric hash configuration failure Reason: operStQual Failed Config: eltmCfgFailedBmp

Help:

Triggered By:
        eltmCfgState not equals 0