Fault fltVpcDomVpcCfgCtrl
Explanation: This fault is caused by a hardware programming failure
Recommended Action: The system will periodically retry to program the hardware. If the failure is due to lack of hardware resources, free up resources by removing or simplifying existing configuration. One of the reasons for lack of hardware resources is exhaustion of VLANs in ToR. These hardware resources can be examined by looking at capacity dashboard under OPERATIONS tab. Please check entry against the number of VLANs in output of command show vlan summary issued at node where fault is generated to check whether it exceeds above advertised node capacity.
Fault Name: fltVpcDomVpcCfgCtrl
Unqualified API Name: vpcCfgCtrl
Code: F1184
Applied Mo DN Format:
topology/pod-[id]/node-[id]/sys/vpc/inst/dom-[id]
sys/vpc/inst/dom-[id]
Type: config
Cause: config-failure
Severity: warning
Weight: 100
Tags:
Message:
vPC domain configuration failure
Help:
Triggered By:
vpcCfgState not equals 0