Fault fltVpcKeepaliveVpcCfgCtrl
                
                    
                         Explanation: This fault is caused by a hardware programming failure
                         Recommended Action: The system will periodically retry to program the hardware. If the failure is due to lack of hardware resources, free up resources by removing or simplifying existing configuration. One of the reasons for lack of hardware resources is exhaustion of VLANs in ToR. These hardware resources can be examined by looking at capacity dashboard under OPERATIONS tab. Please check entry against the number of VLANs in output of command show vlan summary issued at node where fault is generated to check whether it exceeds  above advertised node capacity.
                         
                         
Fault Name: fltVpcKeepaliveVpcCfgCtrl
                         Unqualified API Name: vpcCfgCtrl
                         
                         Code: F1185
                         
                         Applied Mo DN Format: 
                         
                                  topology/pod-[id]/node-[id]/sys/vpc/inst/dom-[id]/keepalive
                             
                                  sys/vpc/inst/dom-[id]/keepalive
                             
                         
                         Type: config
                         
                         Cause: config-failure
                         
                         Severity: warning
                         
                         Weight: 100
                         
                         Tags: 
                         
                         Message: 
vPC keepalive configuration failure
                         
                         Help: 
                         
                         
                         Triggered By: 
                         
                                    vpcCfgState not equals 0