Fault fltL2RsSrvExtIfMapNpvCfgCtrl
                

Rule ID:2447


Explanation: This fault is caused by a hardware programming failure
Recommended Action: The system will periodically retry to program the hardware. If the failure is due to lack of hardware resources, free up resources by removing or simplifying existing configuration. One of the reasons for lack of hardware resources is exhaustion of VLANs in ToR. These hardware resources can be examined by looking at capacity dashboard under OPERATIONS tab. Please check entry against the number of VLANs in output of command show vlan summary issued at node where fault is generated to check whether it exceeds above advertised node capacity.

Raised on MO: l2:RsSrvExtIfMap

Fault Name: fltL2RsSrvExtIfMapNpvCfgCtrl

Unqualified API Name: npvCfgCtrl
Code: F2447
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/fc/vfc-[id]/rssrvExtIfMap-[tDn]
     sys/fc/vfc-[id]/rssrvExtIfMap-[tDn]

Type: config
Cause: config-failure
Severity: warning
Weight: 100
Tags:
Message: NPV Traffic Map Configure Failure

Help:

Triggered By:
        npvCfgState not equals 0