Fault fltCoppFilterPrefilterTcamUnvailable
                

Rule ID:2923


Explanation:
This fault occurs when there is no space available in the TCAM on at least one of the modules. Note: If hw has more than one module, CoPP prefilter ACL entry might have successfully installed on few modules and failed on few modules.

Recommended Action:
To recover from this fault, try the following actions


  1. Delete any unused installed CoPP prefilter ACL entry to make space in the TCAM.

Raised on MO: copp:Filter

Fault Name: fltCoppFilterPrefilterTcamUnvailable

Unqualified API Name: prefilterTcamUnvailable
Code: F2923
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/copp/rulep-[name]-[type]/filter-[action]-prio-[prio]-proto-[ipProto]-src-[srcAddr]-dst-[dstAddr]-srcFromP-[srcPortFrom]-srcToP-[srcPortTo]-dstFromP-[dstPortFrom]-dstToP-[dstPortTo]
     sys/copp/rulep-[name]-[type]/filter-[action]-prio-[prio]-proto-[ipProto]-src-[srcAddr]-dst-[dstAddr]-srcFromP-[srcPortFrom]-srcToP-[srcPortTo]-dstFromP-[dstPortFrom]-dstToP-[dstPortTo]

Type: operational
Cause: copp-prefilter-acl-entry-installation-failed-due-to-unavailability-of-tcam-space
Severity: major
Weight: 100
Tags:
Message: CoPP prefilter ACL entry installation failure reason:operStQual

Help:

Triggered By:
        operStQual equals tcam-unavailable