|  Constants | 
                         
                         
                             |  not-applicable   | 
                             0ull | 
                             N/A | 
                             
                                 NO COMMENTS
                              | 
                         
                         
                             |  san-boot-validation-failed   | 
                             16ull | 
                             Vfc cannot be deployed both on the port channel and its member ports | 
                             
                                 NO COMMENTS
                              | 
                         
                         
                             |  insufficient-resources   | 
                             1ull | 
                             insufficient-resources | 
                             
                                  overall there are not enough resources 
                              | 
                         
                         
                             |  invalid-vsan   | 
                             2ull | 
                             Invalid VSAN Configuration | 
                             
                                  Invalid VSAN Configuration
                                                      The domain associated with the EPg is not allowed to use the specified encap. Check the Attachable Profile,
                                                      VsanAttrP and VSAN Namespace (fvns:VsanInstP) configurations associated with the domain.
                                                      
                              | 
                         
                         
                             |  native-vsan-failure   | 
                             4ull | 
                             Only One Native Vsan Allowed on Interface | 
                             
                                  Native/Untagged Vsan Validation
                                                      You are trying to configure two different vsans as native on the path (i.e. port/port-channel).
                                                      Check the "mode" type set on the relations between the EPg and the fabric:Path.
                                                      
                              | 
                         
                         
                             |  another-encap-for-bd-in-use   | 
                             8ull | 
                             BD is assigned another encap | 
                             
                                  Vsan Encap validation
                                                      If a vsan is already attached to BD, another vsan can not be attached.
                                                      
                              | 
                         
                         
                             |  encap-already-in-use   | 
                             8ull | 
                             Encap Already Used in Another EPG | 
                             
                                  Vsan Encap validation
                                                      On a node, an encap (VSAN) can be used by only 1 EPg or BD at a time.
                                                      
                              | 
                         
                         
                             | DEFAULT  | 
                             not-applicable(0ull) | 
                             N/A | 
                             
                                 NO COMMENTS
                              |