Fault fltEqptStorageFull-Warning
                

Rule ID:1527


Explanation:
This fault occurs when the utilization of storage capacity on a controller is greater than 75%

Recommended Action:
If you see this fault, take the following actions:


  1. Cleanup any files created by the user on the partition on the storage device that the fault was produced on to free up space.
  2. 1) Cleaning of old core files (which are not needed for any investigation) can be accomplished as follows:
  3. In the UI, go to Admin - Import/Export - Export Policies - Core - default - Operational, then click on old core files which are not needed for further use and delete.
  4. 2) Cleaning of techsupport files can be accompolished as follows:
  5. In the UI, go to Admin - Import/Export - Export Policies - default - Operational, then click on individual techsupport files and delete.
  6. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: eqpt:Storage

Fault Name: fltEqptStorageFull-Warning

Unqualified API Name: Full-Warning
Code: F1527
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/ch/p-[mount]-f-[fileSystem]
     sys/ch/p-[mount]-f-[fileSystem]

Type: operational
Cause: equipment-full
Severity: warning
Weight: 100
Tags:
Message: Storage unit name on Node id mounted at mount is capUtilized% full

Help:

Triggered By:
         capUtilized not equals NULL
        and
         capUtilized greater or equal 75
        and
         capUtilized less than 85