Fault fltSpanRsSrcToBDDefConfigFailed
Explanation:
This fault is raised when the fabric
span policy failed to get deployed due to missing BD.
Recommended Action:
If you see this fault, take the
following actions:
Fault Name: fltSpanRsSrcToBDDefConfigFailed
Unqualified API Name: configFailed
Code: F1555
Applied Mo DN Format:
topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/fv-[epgPKey]/srcgrpdef-[name]/src-[name]/rssrcToBDDef
uni/epp/fv-[epgPKey]/srcgrpdef-[name]/src-[name]/rssrcToBDDef
topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/out-[name]/lnodep-[name]/lifp-[name]/rspathL3OutAtt-[tDn]/srcgrpdef-[name]/src-[name]/rssrcToBDDef
uni/tn-[name]/out-[name]/lnodep-[name]/lifp-[name]/rspathL3OutAtt-[tDn]/srcgrpdef-[name]/src-[name]/rssrcToBDDef
topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/infra/srcgrp-[name]/src-[name]/rssrcToBDDef
uni/infra/srcgrp-[name]/src-[name]/rssrcToBDDef
topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/srcgrp-[name]/src-[name]/rssrcToBDDef
uni/tn-[name]/srcgrp-[name]/src-[name]/rssrcToBDDef
topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/fabric/srcgrp-[name]/src-[name]/rssrcToBDDef
uni/fabric/srcgrp-[name]/src-[name]/rssrcToBDDef
Type: config
Cause: configuration-failed
Severity: major
Weight: 100
Tags:
Message:
Failed to configure SPAN with source name due to missing/invalid private layer L2 network context tDn: stateQual(state)
Help:
Triggered By:
state equals missing-target
or
state equals invalid-target
or
state equals unformed