Fault fltFabricProtGEpZoneconfiguration
                

Rule ID:2121


Explanation:
This fault occurs when a virtual Port Channel (vPC) policy is created but nodes are not part of same zone.



Recommended Action:
If you see this fault, take the following actions:


  1. Verify that corresponding fabric nodes are part of same zone configuration by checking Domain ID for Pair of Leaf Nodes in Fabric->Access Policies -> Policies ->Switch->Virtual Port Channel Default .
  2. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: fabric:ProtGEp

Fault Name: fltFabricProtGEpZoneconfiguration

Unqualified API Name: zoneconfiguration
Code: F2121
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/fabric/protpol/
     uni/fabric/protpol/

Type: config
Cause: configuration-failed
Severity: critical
Weight: 100
Tags:
Message: vPC pairs are not configured in same zone. The corresponding node group is name (vpc-explicitGrpNode1Node2)

Help:

Triggered By:
         configQual equals pairs-not-same-zone