Fault fltIpv4NexthopEPIpv4NexthopEpConfigFailed
                
                    
                         Explanation:   
 This fault occurs when
                 Nexthop EP Reachability configuration is deployed on
                 an unsupported platform TOR. The reason could be that
                 this configuration is on a BD that stretches to the
                 unsupported TOR  
                         Recommended Action:   
 If this fault is seen consistently,
                 try the following actions 
                 
Fault Name: fltIpv4NexthopEPIpv4NexthopEpConfigFailed
                         Unqualified API Name: ipv4NexthopEpConfigFailed
                         
                         Code: F2827
                         
                         Applied Mo DN Format: 
                         
                                  topology/pod-[id]/node-[id]/sys/ipv4/inst/dom-[name]/rtipep-[prefix]/addr-[nhAddr]-vrf-[nhVrf]
                             
                                  sys/ipv4/inst/dom-[name]/rtipep-[prefix]/addr-[nhAddr]-vrf-[nhVrf]
                             
                         
                         Type: operational
                         
                         Cause: oper-state-change
                         
                         Severity: warning
                         
                         Weight: 100
                         
                         Tags: 
                         
                         Message: 
IPv4 Nexthop EP Reachability configuration not supported on node                          id                          name
                         
                         Help: 
                         
                         
                         Triggered By: 
                         
                                    operSt equals unsupported