Fault fltStpInstMstpWithLocalScope
                

Rule ID:2875


Explanation:
This fault occurs when some interfaces are in local scope but they are receiving MST (802.1s) BPDUs. It could lead to inconsistent endpoint states in the fabric.

Recommended Action:
To recover from this fault, try the following actions


  1. Configure global scope on the interface
  2. If the above actions did not resolve the issue, generate the show tech-support file and contact Cisco TAC.

Raised on MO: stp:Inst

Fault Name: fltStpInstMstpWithLocalScope

Unqualified API Name: mstpWithLocalScope
Code: F2875
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/stp/inst
     sys/stp/inst

Type: operational
Cause: config-mismatch
Severity: critical
Weight: 100
Tags:
Message: Port local scope is not supported with MST on node id of fabric fabricDomain with a hostname name

Help:

Triggered By:
        stpStQual contains mstp-with-local-scope