Fault fltFvCtxConfigIssuesConfig-failed
                

Rule ID:468


Explanation:
This fault occurs when a given Ctx configured to use a DNS Profile which doesn't configured In Fabric or when BGP RouteTarget Profiles are not configured for Ctx associated to SR-MPLS L3Out.

Recommended Action:
If you see this fault, take the following actions:


  1. For dns-policy-not-present issue: Check the Configuration and make sure that DNS Profile consumed by Ctx is defined in fabric. Only DNS Profiles configured for fabric can be used.
  2. For bgp-route-target-profile-not-present issue: Check the Configuration and make sure that BGP RouteTarget Profiles are configured for Ctx associated to SR-MPLS L3Out.
  3. If the above action did not resolve the issue, create a tech-support file and contact Cisco TAC.


Raised on MO: fv:CtxConfigIssues

Fault Name: fltFvCtxConfigIssuesConfig-failed

Unqualified API Name: config-failed
Code: F0468
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/ctx-[ctxDn]/ctxcfgissues
     uni/ctx-[ctxDn]/ctxcfgissues

Type: config
Cause: configuration-failed
Severity: minor
Weight: 100
Tags:
Message: Ctx Configuration failedCtx Configuration failed for ctxDn due to configQual

Help:

Triggered By:
        configSt equals failed-to-apply