Fault fltSpanRsSrcToCtxDefConfigFailed
                

Rule ID:1554


Explanation:
This fault is raised when the fabric span policy failed to get deployed due to missing Ctx.

Recommended Action:
If you see this fault, take the following actions:


  1. Verify that the Ctx in the relation's target DN is valid and present.
  2. Review the fault message and add missing or remove invalid configuration
  3. If the above actions did not resolve the issue, collect tech-support file and contact Cisco TAC.


Raised on MO: span:RsSrcToCtxDef

Fault Name: fltSpanRsSrcToCtxDefConfigFailed

Unqualified API Name: configFailed
Code: F1554
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/epp/fv-[epgPKey]/srcgrpdef-[name]/src-[name]/rssrcToCtxDef
     uni/epp/fv-[epgPKey]/srcgrpdef-[name]/src-[name]/rssrcToCtxDef
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/out-[name]/lnodep-[name]/lifp-[name]/rspathL3OutAtt-[tDn]/srcgrpdef-[name]/src-[name]/rssrcToCtxDef
     uni/tn-[name]/out-[name]/lnodep-[name]/lifp-[name]/rspathL3OutAtt-[tDn]/srcgrpdef-[name]/src-[name]/rssrcToCtxDef
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/infra/srcgrp-[name]/src-[name]/rssrcToCtxDef
     uni/infra/srcgrp-[name]/src-[name]/rssrcToCtxDef
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/srcgrp-[name]/src-[name]/rssrcToCtxDef
     uni/tn-[name]/srcgrp-[name]/src-[name]/rssrcToCtxDef
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/fabric/srcgrp-[name]/src-[name]/rssrcToCtxDef
     uni/fabric/srcgrp-[name]/src-[name]/rssrcToCtxDef

Type: config
Cause: configuration-failed
Severity: major
Weight: 100
Tags:
Message: Failed to configure SPAN with source name due to missing/invalid private L3 network Context tDn: stateQual(state)

Help:

Triggered By:
         state equals missing-target
        or
         state equals invalid-target
        or
         state equals unformed