Fault fltEthpmFcotBaseInvalidTransceiver
                

Rule ID:1815


Explanation:
This fault occurs when a transceiver is invalid or has hardware issues.

Recommended Action:
To recover from this fault, try the following actions


  1. Remove the defective transceiver and replace with valid one.
  2. Ensure that the transceiver is properly coneected.

Raised on MO: ethpm:FcotBase

Fault Name: fltEthpmFcotBaseInvalidTransceiver

Unqualified API Name: invalidTransceiver
Code: F1815
Applied Mo DN Format:

Type: communications
Cause: invalid-transceiver
Severity: critical
Weight: 100
Tags:
Message: Transceiver is invalid and unable to be brought up in system

Help:

Triggered By:
         isFcotPresent equals yes
        and
         type equals unknown