Fault fltEqptPsuPsuFailed
                

Rule ID:1940


Explanation:
This fault occurs when the Power Supply Unit is in fail state

Recommended Action:
If you see this fault, take the following action:


  1. replace the power supply unit that is failed
  2. If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.


Raised on MO: eqpt:Psu

Fault Name: fltEqptPsuPsuFailed

Unqualified API Name: PsuFailed
Code: F1940
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/extch-[id]/psuslot-[id]/psu
     sys/extch-[id]/psuslot-[id]/psu
     topology/pod-[id]/node-[id]/sys/ch/psuslot-[id]/psu
     sys/ch/psuslot-[id]/psu

Type: operational
Cause: equipment-failed
Severity: major
Weight: 100
Tags:
Message: Power supply unit on Node id with hostname name is failed

Help:

Triggered By:
         operSt equals fail