Fault fltEqptFlashFlash-minor-alarm
                

Rule ID:3074


Explanation:
This fault occurs if the flash lifetime usage has reached 80% endurance limit

Recommended Action:
If you see this fault, take the following actions:


  1. Plan for Switch/Supervisor replacement soon.
  2. If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.


Raised on MO: eqpt:Flash

Fault Name: fltEqptFlashFlash-minor-alarm

Unqualified API Name: flash-minor-alarm
Code: F3074
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/sys/extch-[id]/extchslot-[id]/extchc/flash
     sys/extch-[id]/extchslot-[id]/extchc/flash
     topology/pod-[id]/node-[id]/sys/ch/scslot-[id]/sc/flash
     sys/ch/scslot-[id]/sc/flash
     topology/pod-[id]/node-[id]/sys/ch/fcslot-[id]/fc/flash
     sys/ch/fcslot-[id]/fc/flash
     topology/pod-[id]/node-[id]/sys/ch/lcslot-[id]/lc/flash
     sys/ch/lcslot-[id]/lc/flash
     topology/pod-[id]/node-[id]/sys/ch/supslot-[id]/sup/flash
     sys/ch/supslot-[id]/sup/flash
     topology/pod-[id]/node-[id]/sys/ch/nslot-[id]/nic-[id]/flash
     sys/ch/nslot-[id]/nic-[id]/flash
     topology/pod-[id]/node-[id]/sys/ch/bslot/board/flash
     sys/ch/bslot/board/flash

Type: operational
Cause: equipment-flash-warning
Severity: minor
Weight: 100
Tags:
Message: SSD has reached 80% lifetime and is nearing its endurance limit. Please plan for Switch/Supervisor replacement soon

Help:

Triggered By:
        minorAlarm equals true