Fault fltL3extInstPNoConsLblAssociation
                

Rule ID:3941


Explanation:
This fault occurs when there's no consumer label association for an external EPG in an MPLS L3Out
Recommended Action:
If you see this fault, take the following actions:


  1. Ensure that the external EPG is associated with at least one MPLS consumer label


Raised on MO: l3ext:InstP

Fault Name: fltL3extInstPNoConsLblAssociation

Unqualified API Name: NoConsLblAssociation
Code: F3941
Applied Mo DN Format:
     topology/pod-[id]/node-[id]/local/svc-[name]-id-[id]/uni/tn-[name]/out-[name]/instP-[name]
     uni/tn-[name]/out-[name]/instP-[name]

Type: config
Cause: configuration-missing
Severity: minor
Weight: 100
Tags:
Message: Configuration failed for l3extInstP as there is no MPLS consumer label association

Help:

Triggered By:
        configIssues equals no-conslbl-association