callhome:PredefinedProfile
Predefined destination profile node with required delivery information
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
alertGrpAll | callhome:Boolean (scalar:Enum8) |
This alert group consists of all of the callhome messages | SELECTION: 0 - disabled 1 - enabled |
alertGrpCiscoTac1 | callhome:Boolean (scalar:Enum8) |
Events which are meant for Cisco TAC only | SELECTION: 0 - disabled 1 - enabled |
alertGrpConfiguration | callhome:Boolean (scalar:Enum8) |
Events related to Configuration | SELECTION: 0 - disabled 1 - enabled |
alertGrpDiagnostic | callhome:Boolean (scalar:Enum8) |
Events related to Diagnostic | SELECTION: 0 - disabled 1 - enabled |
alertGrpEEM | callhome:Boolean (scalar:Enum8) |
Events related to EEM | SELECTION: 0 - disabled 1 - enabled |
alertGrpEnvironmental | callhome:Boolean (scalar:Enum8) |
Power,Fan,Temperature related events | SELECTION: 0 - disabled 1 - enabled |
alertGrpInventory | callhome:Boolean (scalar:Enum8) |
Inventory Status Events | SELECTION: 0 - disabled 1 - enabled |
alertGrpLicense | callhome:Boolean (scalar:Enum8) |
Events related to licensing | SELECTION: 0 - disabled 1 - enabled |
alertGrpLinecard | callhome:Boolean (scalar:Enum8) |
Linecard related events | SELECTION: 0 - disabled 1 - enabled |
alertGrpSupervisor | callhome:Boolean (scalar:Enum8) |
Supervisor related events | SELECTION: 0 - disabled 1 - enabled |
alertGrpSyslogPort | callhome:Boolean (scalar:Enum8) |
Events related to syslog messages filed by port manager | SELECTION: 0 - disabled 1 - enabled |
alertGrpSystem | callhome:Boolean (scalar:Enum8) |
Software related events | SELECTION: 0 - disabled 1 - enabled |
alertGrpTest | callhome:Boolean (scalar:Enum8) |
User generated test events | SELECTION: 0 - disabled 1 - enabled |
format | callhome:Format (scalar:Enum8) |
Callhome message format to be sent to configured profile | SELECTION: 1 - xml 2 - full-txt 3 - short-txt DEFAULT: xml |
messageLevel | scalar:Uint32 |
Callhome message-level for the configured profile | RANGE: [0 , 9] DEFAULT: 0 |
messageSize | scalar:Uint32 |
Callhome message-size for the configured profile | RANGE: [0 , 5000000] DEFAULT: 2500000 |
predefProfile | callhome:PredefProfileName (scalar:Enum8) |
Predefined destination profile names | SELECTION: 0 - predef_tac_prof 1 - full_txt 2 - short_txt |
transportMethodEmail | callhome:Boolean (scalar:Enum8) |
Trnasport method as email | SELECTION: 0 - disabled 1 - enabled DEFAULT: enabled |
transportMethodHttp | callhome:Boolean (scalar:Enum8) |
Transport method as http | SELECTION: 0 - disabled 1 - enabled DEFAULT: disabled |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |