callhome:PredefinedProfile

Predefined destination profile node with required delivery information

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
alertGrpAll callhome:Boolean
(scalar:Enum8)
This alert group consists of all of the callhome messages SELECTION:
0 - disabled
1 - enabled
alertGrpCiscoTac1 callhome:Boolean
(scalar:Enum8)
Events which are meant for Cisco TAC only SELECTION:
0 - disabled
1 - enabled
alertGrpConfiguration callhome:Boolean
(scalar:Enum8)
Events related to Configuration SELECTION:
0 - disabled
1 - enabled
alertGrpDiagnostic callhome:Boolean
(scalar:Enum8)
Events related to Diagnostic SELECTION:
0 - disabled
1 - enabled
alertGrpEEM callhome:Boolean
(scalar:Enum8)
Events related to EEM SELECTION:
0 - disabled
1 - enabled
alertGrpEnvironmental callhome:Boolean
(scalar:Enum8)
Power,Fan,Temperature related events SELECTION:
0 - disabled
1 - enabled
alertGrpInventory callhome:Boolean
(scalar:Enum8)
Inventory Status Events SELECTION:
0 - disabled
1 - enabled
alertGrpLicense callhome:Boolean
(scalar:Enum8)
Events related to licensing SELECTION:
0 - disabled
1 - enabled
alertGrpLinecard callhome:Boolean
(scalar:Enum8)
Linecard related events SELECTION:
0 - disabled
1 - enabled
alertGrpSupervisor callhome:Boolean
(scalar:Enum8)
Supervisor related events SELECTION:
0 - disabled
1 - enabled
alertGrpSyslogPort callhome:Boolean
(scalar:Enum8)
Events related to syslog messages filed by port manager SELECTION:
0 - disabled
1 - enabled
alertGrpSystem callhome:Boolean
(scalar:Enum8)
Software related events SELECTION:
0 - disabled
1 - enabled
alertGrpTest callhome:Boolean
(scalar:Enum8)
User generated test events SELECTION:
0 - disabled
1 - enabled
format callhome:Format
(scalar:Enum8)
Callhome message format to be sent to configured profile SELECTION:
1 - xml
2 - full-txt
3 - short-txt
DEFAULT: xml
messageLevel scalar:Uint32
Callhome message-level for the configured profile
RANGE: [0 , 9]
DEFAULT: 0
messageSize scalar:Uint32
Callhome message-size for the configured profile
RANGE: [0 , 5000000]
DEFAULT: 2500000
predefProfile callhome:PredefProfileName
(scalar:Enum8)
Predefined destination profile names SELECTION:
0 - predef_tac_prof
1 - full_txt
2 - short_txt
transportMethodEmail callhome:Boolean
(scalar:Enum8)
Trnasport method as email SELECTION:
0 - disabled
1 - enabled
DEFAULT: enabled
transportMethodHttp callhome:Boolean
(scalar:Enum8)
Transport method as http SELECTION:
0 - disabled
1 - enabled
DEFAULT: disabled

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced