sla:TwampResponder
sla Responder twamp specific configs are handled with this mo
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
adminState | scalar:Bool |
Enable or disable the twamp responder. To enable twamp responder, feature sla responder is to be enabled | SELECTION: true or false DEFAULT: FALSE |
timeout | sla:Timeout (scalar:Uint32) |
TWAMP Responder Session inactivity timeout in seconds (default 900) | RANGE: [1 , 604800] DEFAULT: 900 |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |