sflow:Inst
Instance for Sflow config
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
adminSt | nw:AdminSt (scalar:Enum8) |
The administrative state of the object or policy. | SELECTION: 1 - enabled 2 - disabled DEFAULT: enabled |
agentAddress | sflow:addressIp (address:Ip) |
The IP address associated with this agent. In the case of a multi-homed agent, this should be the loopback address of the agent.The address should be an invariant that does not change as interfaces are reconfigured, enabled, disabled, added or removed | Value must match ipv4 or ipv6 known format |
counterPollInterval | sflow:counterPollInterval (scalar:Uint32) |
The maximum number of seconds between successive samples of the counters associated with this data source | RANGE: [0 , 2147483647] DEFAULT: 20 |
ctrl | nw:InstCtrl (scalar:Bitmask64) |
The control state. | SELECTION: 1 - stateful-ha |
isExtendedBgp | scalar:Bool |
Describes whether sflow is configured in extended bgp flow | SELECTION: true or false |
isExtendedSwitch | scalar:Bool |
Describes whether sflow is configured in extended switch flow | SELECTION: true or false |
maxHeaderSize | sflow:maxSampledSize (scalar:Uint32) |
The maximum number of bytes that should be copied from a sampled packet. The agent may have an internal maximum and minimum permissible sizes | RANGE: [64 , 256] DEFAULT: 128 |
pktSamplingRate | sflow:samplingRate (scalar:Uint32) |
The statistical sampling rate for packet sampling from this source | RANGE: [0, 4294967295] |
rcvrAddress | sflow:addressIp (address:Ip) |
The IP address of the sFlow collector. If set to 0.0.0.0 not sFlow datagrams will be sent. | Value must match ipv4 or ipv6 known format |
rcvrMaxDatagramSize | sflow:maxDatagramSize (scalar:Uint32) |
The maximum number of data bytes that can be sent in a single sample datagram | RANGE: [200 , 9000] DEFAULT: 1400 |
rcvrPort | sflow:L4Port (scalar:Uint32) |
The destination port for sFlow datagrams. | RANGE: [1 , 65535] DEFAULT: 6343 |
rcvrSrcAddress | sflow:addressIp (address:Ip) |
The source ip-address option causes the sent sFlow datagram to use the source IP address as the IP packet source address. | Value must match ipv4 or ipv6 known format |
rcvrVrfName | sflow:VrfName (string:Basic) |
It holds collector vrf name | A sequence of characters |
Operational Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
operErr | nw:OperErrQual (scalar:Bitmask64) |
Operational Errors Qualifier | SELECTION: 1 - init-err 2 - mem-err 4 - ipc-err 8 - int-err 16 - sock-err 32 - proto-err |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
name | naming:Name256 (string:Basic) |
The name of the object. | MAX SIZE: 128 |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |