itd:IngressIf

Telemetry Sensor Path(s)

Operational Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
generatedTrackID itd:TrackId
(scalar:Uint32)
Software auto generated track id
RANGE: [0 , 512]
DEFAULT: 0
probestatus itd:ProbeStatus
(scalar:Enum8)
runtime state of interface probe SELECTION:
0 - inactive
1 - standby
2 - link-failed
3 - probe-failed
4 - peer-down
5 - active
6 - hold-down
7 - shut
DEFAULT: inactive
propFaultBitmap itd:ingressIfFaultBitmapT
(scalar:Bitmask64)
Error state for the ingress interface. SELECTION:
1 - if-conf-err
2 - if-svc-tbl-full-err
4 - if-svc-missing-err
8 - if-svc-enabled-err
16 - if-svc-create-err
32 - if-not-l3-err
64 - if-invalid-err
128 - if-vrf-mismatch-err
256 - if-max-limit-err

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
name nw:IfId
(base:IfIndex)
The name of the object. Must match first field in the output of show intf brief. Example: Eth1/1 or Vlan100
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced