ipqos:PriorFlowCtrlWd

priority flow control watchdog

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
disableAction scalar:Bool
only generate syslog for stuck queue, no action SELECTION: true or false
DEFAULT: false
interfaceMutiplier ipqos:PriorFlowCtrlWdIntfMulti
(scalar:UByte)
shutdown mutlipler value
RANGE: [1 , 10]
watchDogInterval ipqos:PriorFlowCtrlWdIntvl
(scalar:Enum8)
watch dog internal on/off SELECTION:
1 - on
2 - off
DEFAULT: off

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced