bgp:MhBfdIntvl

Configure BFD session interval parameters

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
minRxMs bgp:MhTxRxIntvlT
(scalar:Uint16)
Minimum receive interval in milliseconds
RANGE: [250 , 999]
minTxMs bgp:MhTxRxIntvlT
(scalar:Uint16)
Minimum transmit interval in milliseconds
RANGE: [250 , 999]
multiplier bgp:MultiplierT
(scalar:Uint16)
Detect multiplier for bfd sessions
RANGE: [1 , 50]

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced