eqpt:ConsoleP
The console policy.
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| descr | pol:Descr | 
Description of the specified attribute | |
| name | pol:ObjName (naming:Name256)  | 
Object name | MAX SIZE: 64  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| baudRate | eqpt:BaudRate (scalar:Enum8)  | 
Baud Rate | SELECTION:  1     - 300  2     - 1200  3     - 2400  4     - 4800  5     - 9600  6     - 38400  7     - 57600  8     - 115200 DEFAULT: 115200  | 
| dataBits | eqpt:DataBits (scalar:Uint16)  | 
Data Bits | RANGE: [5 , 8] DEFAULT: 8  | 
| inactiveIntvl | eqpt:InactiveIntvl (scalar:Uint32)  | 
Inactive Interval | RANGE: [0 , 525600] DEFAULT: 0  | 
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| parity | eqpt:Parity (scalar:Enum8)  | 
Parity | SELECTION:  0     - none  1     - even  2     - odd DEFAULT: none  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  | 
| stopBits | eqpt:StopBits (scalar:Uint16)  | 
Stop Bits | RANGE: [1 , 2] DEFAULT: 1  |