eqpt:PsgP

The power supply group policy.

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
adminRdnM eqpt:PsRdnM
(scalar:Enum8)
Admin redundancy mode
comb, comb-force, insrc-rdn, ps-rdn
SELECTION:
0 - unknown
1 - not-supp
2 - rdn
3 - comb
4 - n-rdn
5 - ps-rdn
6 - insrc-rdn
7 - sinin-rdn
8 - comb-force
DEFAULT: ps-rdn
descr pol:Descr
Description of the specified attribute
name pol:ObjName
(naming:Name256)
Object name
MAX SIZE: 64

Operational Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
acRdnCap eqpt:Watts
(scalar:Uint32)
AC Redundant Capacity RANGE: [0, 4294967295]
alPwr eqpt:Watts
(scalar:Uint32)
Value is same as 'Total Power Allocated (budget)' shown in show environment power
Allocated power in watts
RANGE: [0, 4294967295]
avPwr eqpt:Watts
(scalar:Uint32)
Value is same as 'Total Power Available for additional modules' shown in show environment power
The available power measured in watts.
RANGE: [0, 4294967295]
cordsConnected scalar:Bool
It is shown if all inlet cords connected SELECTION: true or false
flRdnCap eqpt:Watts
(scalar:Uint32)
Power capacity under full redundancy. It is calculated as the minimum of ps and grid redundancy RANGE: [0, 4294967295]
grdACap eqpt:Watts
(scalar:Uint32)
The power supply Grid-A total power capacity RANGE: [0, 4294967295]
grdBCap eqpt:Watts
(scalar:Uint32)
The power supply Grid-B total power capacity RANGE: [0, 4294967295]
grdRdnCap eqpt:Watts
(scalar:Uint32)
power capacity under grid redundancy RANGE: [0, 4294967295]
inputDraw eqpt:Watts
(scalar:Uint32)
The power supply total power input (actual draw) RANGE: [0, 4294967295]
nRdnCap eqpt:Watts
(scalar:Uint32)
Available power under various redundancy modes Cumulative power available in non-redundant mode. It is obtained by summing the individual power provided by all present and functioning psu RANGE: [0, 4294967295]
operRdnM eqpt:PsRdnM
(scalar:Enum8)
Value is same as 'Power Supply redundancy mode (operational)' shown in show environment power
The power supply redundancy operational mode
SELECTION:
0 - unknown
1 - not-supp
2 - rdn
3 - comb
4 - n-rdn
5 - ps-rdn
6 - insrc-rdn
7 - sinin-rdn
8 - comb-force
DEFAULT: ps-rdn
outputDraw eqpt:Watts
(scalar:Uint32)
The power supply total power output (actual draw) RANGE: [0, 4294967295]
psRdnCap eqpt:Watts
(scalar:Uint32)
power capacity under power supply redundancy RANGE: [0, 4294967295]
rsdPwr eqpt:Watts
(scalar:Uint32)
Reserved power in watts RANGE: [0, 4294967295]
tc eqpt:Watts
(scalar:Uint32)
Value is same as 'Total Power Capacity (based on configured mode)' shown in show environment power
total power capacity in watts. It depends on the redundancy mode and is equal to one of cumCap
RANGE: [0, 4294967295]
unit string:Basic
The power supply unit A sequence of characters

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced