fsyncMgr:SynceEntity

synce MO for global configuration

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
clockid address:MAC
SyncE clock-identity MAC Address Value must match MM:MM:MM:SS:SS:SS format
peerrcvtimeout fsyncMgr:peerrcvtimeout
(scalar:Uint16)
fsync esmc peer receive timeout in seconds, (120-600) default: 0
RANGE: [0 , 600]
DEFAULT: 120
qloption fsyncMgr:gqloptype
(scalar:Enum8)
QL option type global SELECTION:
1 - op1
2 - op2g1
3 - op2g2
DEFAULT: op1
txDnuLag scalar:Bool
transmit dnu on lag members SELECTION: true or false
DEFAULT: true

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced