l1:LoadP
A load interval policy.
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
loadIntvl1 | l1:LoadIntvl (scalar:Uint16) |
The port load sampling interval 1 at bit-rate and packet-rate statistics. | RANGE: [5 , 300] DEFAULT: 30 |
loadIntvl2 | l1:LoadIntvl (scalar:Uint16) |
The port load sampling interval 2 at bit-rate and packet-rate statistics. | RANGE: [5 , 300] DEFAULT: 300 |
loadIntvl3 | l1:LoadIntvl3 (scalar:Uint16) |
The port load sampling interval 3 at bit-rate and packet-rate statistics. | RANGE: [0 , 300] DEFAULT: 0 |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |