platform:PacketDrop
Packet Drop config
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
captureCount | scalar:Uint16 |
Packet Drop Capture Count | RANGE: [2 , 1024] DEFAULT: 304 |
captureTimer | scalar:Uint16 |
Packet Drop Capture Timer (Micro-Seconds) | RANGE: [1 , 429] |
dropTrigger | platform:TriggerType (scalar:Enum8) |
Packet Drop Trigger | SELECTION: 0 - wred 1 - ingress-admission 2 - egress-admission DEFAULT: wred |
packetDropEnable | scalar:Bool |
Packet Drop Enable | SELECTION: true or false DEFAULT: false |
postTriggerSampling | scalar:UByte |
Packet Drop Post-Sampling Rate | RANGE: [1 , 16] DEFAULT: 16 |
preTriggerSampling | scalar:UByte |
Packet Drop Pre-Sampling Rate | RANGE: [1 , 16] DEFAULT: 8 |
sourceInterface | nw:IfId (base:IfIndex) |
Capture Entity | Must match first field in the output of show intf brief . Example: Eth1/1 or Vlan100 |
sourceInterfaceQosGrp | scalar:UByte |
Capture Entity QosGroup | RANGE: [0 , 8] DEFAULT: 0 |
sourceScope | platform:SourceScope (scalar:Enum8) |
Packet Drop Capture Scope | SELECTION: 0 - unicast-queue 1 - ingress-port 2 - egress-port DEFAULT: unicast-queue |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |