platform:PriorFlowCtrlWd

PFC WD config

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
autoRestoreMultiplier scalar:UByte
PFC WD Auto shutdown multiplier
RANGE: [0 , 100]
DEFAULT: 10
cfgMode platform:ConfigOnOff
(scalar:Enum8)
PFC WD enabled SELECTION:
0 - off
1 - on
DEFAULT: off
fixedRestoreMultiplier scalar:UByte
PFC WD Fixed shutdown multiplier
RANGE: [0 , 100]
DEFAULT: 0
forcedOn platform:ConfigOnOff
(scalar:Enum8)
PFC WD forced on SELECTION:
0 - off
1 - on
DEFAULT: off
internalIntfMultiplier scalar:UByte
PFC WD Internal interface multiplier
RANGE: [0 , 10]
DEFAULT: 2
interval scalar:Uint16
PFC WD poll interval
RANGE: [100 , 1000]
DEFAULT: 100
shutdownMultiplier scalar:UByte
PFC WD Shutdown multiplier
RANGE: [1 , 10]
DEFAULT: 1

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced