platform:PriorFlowCtrlWd
PFC WD config
Telemetry Sensor Path(s)
Configurable Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
---|---|---|---|
autoRestoreMultiplier | scalar:UByte |
PFC WD Auto shutdown multiplier | RANGE: [0 , 100] DEFAULT: 10 |
cfgMode | platform:ConfigOnOff (scalar:Enum8) |
PFC WD enabled | SELECTION: 0 - off 1 - on DEFAULT: off |
fixedRestoreMultiplier | scalar:UByte |
PFC WD Fixed shutdown multiplier | RANGE: [0 , 100] DEFAULT: 0 |
forcedOn | platform:ConfigOnOff (scalar:Enum8) |
PFC WD forced on | SELECTION: 0 - off 1 - on DEFAULT: off |
internalIntfMultiplier | scalar:UByte |
PFC WD Internal interface multiplier | RANGE: [0 , 10] DEFAULT: 2 |
interval | scalar:Uint16 |
PFC WD poll interval | RANGE: [100 , 1000] DEFAULT: 100 |
shutdownMultiplier | scalar:UByte |
PFC WD Shutdown multiplier | RANGE: [1 , 10] DEFAULT: 1 |
Internal Properties
PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
---|---|---|---|
modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |