sla:Reaction
sla reaction configurations for a probe - IP SLAs reactions are configured to trigger when a monitored value exceeds or falls below a specified level or when a monitored event, such as a timeout or connection loss, occurs. If IP SLAs measure too high or too low of any configured reaction, IP SLAs can generate a notification to a network management application or trigger another IP SLA operation to gather more data.
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| lowerThreshold | sla:Threshold (scalar:Uint32)  | 
Lower limit for Threshold. | RANGE: [1 , 60000] DEFAULT: 3000  | 
| reactOn | sla:ReactionVariable (scalar:Enum8)  | 
The performance parameters on which the proactive threshold monitoring and notifications are done. | SELECTION:  0     - none  1     - rtt  2     - jitterSDAvg  3     - jitterDSAvg  4     - packetLossSD  5     - packetLossDS  6     - mos  7     - timeout  8     - connectionLoss  9     - verifyError  10    - jitterAvg  11    - icpif  13    - packetLateArrival  14    - packetOutOfSequence  15    - maxOfPositiveSD  16    - maxOfNegativeSD  17    - maxOfPositiveDS  18    - maxOfNegativeDS DEFAULT: none  | 
| reactionType | sla:ActionType (scalar:Enum8)  | 
The config is to notify the user when the monitored performance parameter value rises above or falls below a specified threshold. The notification can be either as SNMP traps or trigger to a new probe. | SELECTION:  1     - none  2     - trapOnly  3     - triggerOnly  4     - trapAndTrigger DEFAULT: none  | 
| thresholdCountX | scalar:Uint16 | 
The config denotes the number of times the monitored performance parameter value rises above or falls below a specified threshold. This config applies only for the thresholdType 1. average 2. consecutive 3. xOfy | RANGE: [1 , 16] DEFAULT: 5  | 
| thresholdCountY | scalar:Uint16 | 
The config denotes the number of times the monitored performance parameter value rises above or falls below a specified threshold. This config applies only for the thresholdType xOfy | RANGE: [1 , 16] DEFAULT: 5  | 
| thresholdType | sla:ThresholdType (scalar:Enum8)  | 
The config says when the configured reactionType should be triggered. | SELECTION:  1     - never  2     - immediate  3     - consecutive  4     - xOfy  5     - average DEFAULT: never  | 
| upperThreshold | sla:Threshold (scalar:Uint32)  | 
Upper limit for Threshold. | RANGE: [1 , 60000] DEFAULT: 5000  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  |