flexlink:Interface
Interface configuration and management for Flexlink
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| backupIntf | nw:IfId (base:IfIndex)  | 
Backup Interface configuration for flexlink | Must match first field in the output of show intf brief. Example: Eth1/1 or Vlan100 | 
| fastConv | scalar:Enum8 | 
multicast fast-convergence configuration for flexlink | DEFAULT: disabled  | 
| id | nw:IfId (base:IfIndex)  | 
Interface ID | Must match first field in the output of show intf brief. Example: Eth1/1 or Vlan100 | 
| preemptionDelay | flexlink:Delay (scalar:Uint32)  | 
switchport backup interface preemption delay configuration for flexlink | RANGE: [1 , 300] DEFAULT: 35  | 
| preemptionMode | flexlink:Mode (scalar:Enum8)  | 
switchport backup interface preemption mode configuration for flexlink | SELECTION:  0     - off  1     - forced  2     - bandwidth DEFAULT: off  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  |