lcm:SysMod
lcm system module object
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| moduleEmonEnhanced | lcm:ModuleEmonEnhanced (scalar:Enum8)  | 
Configure module emon enhanced status | SELECTION:  0     - disable  1     - enable DEFAULT: enable  | 
| moduleEmonEnhancedSlowTimeout | lcm:ModuleEmonEnhancedSlowTimeout (scalar:Enum8)  | 
Configure module emon enhanced slow timeout status | SELECTION:  0     - disable  1     - enable DEFAULT: enable  | 
| moduleEmonEnhancedTimeoutMultiplier | scalar:Uint32 | 
Configure module emon enhanced timeout Multiplier | RANGE: [0, 4294967295] DEFAULT: 1  | 
| moduleFailureAction | lcm:ModuleFailureAction (scalar:Enum8)  | 
Configure module action on failure | SELECTION:  0     - no  1     - shutdown DEFAULT: no  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  |