platform:FlowDedup
Deduplication
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| absoluteTimer | scalar:Uint32 | 
Absolute Timer for Dedup of flows | RANGE: [0 , 1440] DEFAULT: 60  | 
| dedupMode | platform:DedupMode (scalar:Enum8)  | 
Dedup Mode Interface/Vlan | SELECTION:  0     - vlan  1     - interface DEFAULT: vlan  | 
| dynamicTimer | scalar:Uint32 | 
Dynamic Timer for Dedup of flows | RANGE: [0 , 300000] DEFAULT: 500  | 
| enable | scalar:Bool | 
Flow Dedup feature enable | SELECTION: true or false DEFAULT: false  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  |