sysmgr:MemAlert

To configure sysmgr memory alert in embedded event manager.

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
adminSt sysmgr:AdminState
(scalar:Enum8)
State to configure sysmgr memory limit SELECTION:
0 - enable
1 - disable
DEFAULT: disable
applet string:Basic
Applet name used to override default policy of memory alert. A sequence of characters
clear scalar:Uint32
clear memory threshold between 1 to 99
RANGE: [1 , 99]
major scalar:Uint32
Major memory threshold between 1 to 99
RANGE: [1 , 99]
minor scalar:Uint32
Minor memory threshold between 1 to 99
RANGE: [1 , 99]
module scalar:Uint32
module number optional. RANGE: [0, 4294967295]
DEFAULT: 0

Operational Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
operSt sysmgr:OperState
(scalar:Enum8)
Operational status set by sysmgr SELECTION:
0 - unknown
1 - enabled
2 - disabled
DEFAULT: unknown

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
Modification status SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced