sysmgr:SwitchOverAlert

To configure sysmgr switch over alert in embedded event manager.

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
adminSt sysmgr:AdminState
(scalar:Enum8)
State to configure sysmgr switch over alert SELECTION:
0 - enable
1 - disable
DEFAULT: disable
applet string:Basic
Applet name used to override default policy of switch over alert. A sequence of characters
count scalar:Uint32
Expected Number of switch over to trigger event [1-65000]
RANGE: [1 , 65000]
time scalar:Uint32
Expected Time interval to trigger event, in seconds [1-4294967295]
RANGE: [1 , 4294967295]

Operational Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
operSt sysmgr:OperState
(scalar:Enum8)
Operational status set by sysmgr SELECTION:
0 - unknown
1 - enabled
2 - disabled
DEFAULT: unknown

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
Modification status SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced