| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES |
|---|---|---|---|
| controllerBurstPPS | scalar:Uint16 |
Openflow Channel Packets to Controller In PPS | RANGE: [0 , 65535] DEFAULT: 0 |
| datapathId | string:Basic |
OpenFlow Protocol Datapath Id | RANGE: [0 , 20] |
| defaultMiss | scalar:Enum8 |
Openflow Default Miss flow action | DEFAULT: drop |
| logFlowMod | scalar:Bool |
OpenFlow Mod Requests Logging Enable | SELECTION: true or false DEFAULT: false |
| maxBackOff | scalar:Uint16 |
Openflow Protocol Max Backoff Timer | RANGE: [1 , 65535] DEFAULT: 8 |
| packetInPPS | scalar:Uint16 |
Openflow Channel Packets In Rate in PPS | RANGE: [0 , 65535] DEFAULT: 0 |
| probeInterval | scalar:Uint16 |
Openflow Protocol Probe Interval | RANGE: [5 , 65535] DEFAULT: 180 |
| protoVersion | scalar:Enum8 |
Openflow Protocol Version | DEFAULT: Negotiate |
| shutdown | nw:AdminSt (scalar:Enum8) |
Shutdown OpenFlow Switch Instance | SELECTION: 1 - enabled 2 - disabled DEFAULT: disabled |
| sourceIpAddr | address:Ip |
Source IP Addr for Connection to OpenFlow Controller | Value must match ipv4 or ipv6 known format |
| statsCollectInterval | scalar:Uint16 |
OpenFlow Statistics Collection Interval | RANGE: [0 , 600] DEFAULT: 7 |
Internal Properties
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES |
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date) |
The time when this object was last modified. | SELECTION: 0 - never DEFAULT: never |
| status | mo:ModificationStatus (scalar:Bitmask32) |
The upgrade status. This property is for internal use only. | SELECTION: 2 - created 4 - modified 8 - deleted 16 - replaced |